Chapter 4 Parameters
|
4-106
Revision Nov. 2008, VLE1, SW V1.03
suspension ration 1:1
suspension ration 2:1
reel
reel
11-02
sheave diameter
carriage
carriage
pully
pully
pully
pully
load weight
load weight
11-05
Inertial Ratio
Unit: 1
Control
mode
FOCPG
FOCPM
Factory Setting: 40
Settings
1 to 300%
The load inertia can be calculated by the settings of motor parameter, Pr.11-02 Sheave
Diameter, Pr.11-14 Motor Current at Accel. and Pr.11-15 Elevator Acceleration. This
parameter can be used to adjust inertia ratio of load.
11-06
Zero-speed Bandwidth
Unit: 1
11-07
Low-speed Bandwidth
Unit: 1
11-08
High-speed Bandwidth
Unit: 1
Control
mode
FOCPG
FOCPM
Factory Setting: 10
Settings
0 to 40Hz
After estimating inertia and set Pr.11-00=1 (auto tuning), user can adjust parameters Pr.11-06,
11-07 and 11-08 separately by speed response. The larger number you set, the faster
response you will get. Pr.10-08 is the switch frequency for low-speed/high-speed bandwidth.
11-09
PDFF Gain Value
Unit: 1
Control
mode
FOCPG
FOCPM
Factory Setting: 30
Settings
0 to 200%
Summary of Contents for Elevator Drive VFD-VL
Page 1: ......
Page 2: ......
Page 3: ......
Page 21: ...Chapter 1 Introduction 1 12 Revision Nov 2008 VLE1 SW V1 03 20 30HP 15 22kW frame D...
Page 25: ...Chapter 1 Introduction 1 16 Revision Nov 2008 VLE1 SW V1 03 This page intentionally left blank...
Page 205: ...Appendix B Accessories B 8 Revision Nov 2008 VLE1 SW V1 03 VFDB4132 VFDB4132 CHARGE ACT OC OH...
Page 238: ...Appendix B Accessories Revision Nov 2008 VLE1 SW V1 03 B 41 Order P N 200TDDS84C...
Page 243: ...Appendix B Accessories B 46 Revision Nov 2008 VLE1 SW V1 03 This page intentionally left blank...