Chapter 4 Parameters
|
Revision Nov. 2008, VLE1, SW V1.03 4-61
05-19
Accumulative Motor Operation Time (Day)
Unit: 1
Control
mode
VF
VFPG
SVC
FOCPG TQCPG
Factory setting: 00
Settings
00 to 65535
Pr. 05-18 and Pr.05-19 are used to record the motor operation time. They can be cleared by
setting to 00 and time which is less than 60 seconds will not be recorded.
05-20
Core Loss Compensation
Unit: 1
Control
mode
SVC
Factory setting: 10
Settings
0 to 250%