Chapter 4 Parameters
|
Revision Nov. 2008, VLE1, SW V1.03 4-103
10-17
10-13
10-14
10-15
10-16
Hz
PI
10-11
10-12
0Hz
10-20
10-21
10-22
Operation Time of Zero Speed
Unit: 0.001
Control
mode
FOCPM
Factory Setting: 0.250
Settings
0.001 to 65.535sec
10-23
Filter Time of Zero Speed
Unit: 0.001
Control
mode
FOCPM
Factory Setting: 0.004
Settings
0.001 to 65.535sec
10-24
Time for Executing Zero Speed
Control
mode
FOCPM
Factory Setting: 0
Settings
0
After the brake release set in Pr.02-29
1
After the brake signal input (Pr.02-01~02-08 is set to 42)
When Pr.10-24=0, the zero speed control needs to be used with Pr.02-29. (refer to the
explanations in Pr.02-32)