Chapter 4 Parameters
|
4-76
Revision Nov. 2008, VLE1, SW V1.03
07-05
Start-Point for DC Brake
Unit: 0.01
Control
mode
VF
VFPG
SVC
FOCPG
Factory Setting: 0.00
Settings
0.00 to 120.00Hz
This parameter determines the frequency when DC Brake will begin during deceleration. When
the setting is less than start frequency (Pr.01-09), start-point for DC brake will begin from the
min. frequency.
ON
OFF
01-09
07-05
Output freque ncy
Run /Stop
Time
DC Brake Time
DC Brake Time
during St opping
Start
frequen cy
Start-point for
DC brake
time during
stopping
07-0 3
07-0 4
07-06
DC Brake Proportional Gain
Unit: 1
Control
mode
VF
VFPG
SVC
Factory Setting: 50
Settings
1 to 500Hz
It is used to set the output voltage gain when DC brake.
07-07
Dwell Time at Accel.
Unit: 0.01
Control
mode
VF
VFPG
SVC
FOCPG FOCPM
Factory Setting: 0.00
Settings
0.00 to 600.00 sec
07-08
Dwell Frequency at Accel.
Unit: 0.01
Control
mode
VF
VFPG
SVC
FOCPG FOCPM
Factory Setting: 0.00
Settings
0.00 to 120.00 Hz
07-09
Dwell Time at Decel.
Unit: 0.01
Control
mode
VF
VFPG
SVC
FOCPG FOCPM
Factory Setting: 0.00
Settings
0.00 to 600.00 sec
07-10
Dwell Frequency at Decel.
Unit: 0.01
Control
mode
VF
VFPG
SVC
FOCPG FOCPM
Factory Setting: 0.00
Settings
0.00 to 120.00 Hz
In the heavy load situation, Dwell can make stable output frequency temporarily.
Summary of Contents for Elevator Drive VFD-VL
Page 1: ......
Page 2: ......
Page 3: ......
Page 21: ...Chapter 1 Introduction 1 12 Revision Nov 2008 VLE1 SW V1 03 20 30HP 15 22kW frame D...
Page 25: ...Chapter 1 Introduction 1 16 Revision Nov 2008 VLE1 SW V1 03 This page intentionally left blank...
Page 205: ...Appendix B Accessories B 8 Revision Nov 2008 VLE1 SW V1 03 VFDB4132 VFDB4132 CHARGE ACT OC OH...
Page 238: ...Appendix B Accessories Revision Nov 2008 VLE1 SW V1 03 B 41 Order P N 200TDDS84C...
Page 243: ...Appendix B Accessories B 46 Revision Nov 2008 VLE1 SW V1 03 This page intentionally left blank...