Error Code
Message Information
SEC0031
Message
The chassis is open while the power is on.
LCD Message
Intrusion detected. Check chassis cover.
Details
The chassis is open. System performance may be degraded, and
security may be compromised.
Action
Close the chassis. Check system logs.
SEC0033
Message
The chassis is open while the power is off.
LCD Message
Intrusion detected. Check chassis cover.
Details
The chassis was opened while the power was off. System security
may have been compromised.
Action
Close the chassis and verify hardware inventory. Check system logs.
SEL0006
Message
All event logging is disabled.
Details
This message is displayed when all event logging has been disabled
by the user.
Action
If unintended, re-enable logging.
SEL0008
Message
Log is full.
Details
When the event log is full, additional events are not written to the log.
Older events may be overwritten and lost. This message may also
appear if the user disabled event logging.
Action
Backup and clear log.
SEL0012
Message
Could not create or initialize the system event log.
Details
If the system event log fails to initialize, platform status and failure
events are not captured. Some management software do not report
platform exceptions.
Action
Reboot the management controller or iDRAC. Cycle system input
power. If problem persists call support.
SEL1204
Message
An unknown system hardware failure detected.
LCD Message
Unknown system hardware failure.
Details
If the system event log failed to initialize, platform status and failure
events are not captured. Some management software do not report
platform exceptions.
139
Summary of Contents for PowerEdge R820
Page 1: ...Dell PowerEdge R820 Owner s Manual Regulatory Model E21S Series Regulatory Type E21S001 ...
Page 8: ...8 ...
Page 32: ...32 ...
Page 42: ...Figure 15 Memory Socket Locations on the System Board 42 ...
Page 124: ...124 ...
Page 142: ...142 ...