BMC Management Utility
39
Subcommands
status
— Displays the current power status of the system, the returned value is “on” or “off”.
on
— Turns on the managed system.
off
— Issues a “graceful shutdown” IPMI command.
NOTE:
The off subcommand is not supported on the PowerEdge 7250. You must use the force option to
turn off the system.
cycle
— Turns off the system, pauses, then turns the system back on.
reset
— Pulses the system reset signal, regardless of the power state.
Options
-force
This option simulates pressing the power button, forcing the system to turn off without shutting
down the operating system.
Default Subcommand
If a subcommand is not specified, this command acts the same as
power status
.
Figure 3-7. power Option Example