24
Configuring Your Managed System
www
.del
l.
com |
su
ppo
rt.
d
e
ll.
co
m
Figure 2-4. Serial Over LAN Configuration Screen
After configuring the SOL information, click
Save
to complete this subtask.
Enable Serial Over LAN
This check box is used to enable or disable the serial over LAN capability.
SOL Privilege Level
This setting is used to select the minimum BMC privilege level that is required to be able to
activate SOL. The choices are User, Operator, and Administrator. For the best performance, User
should be selected.
Number of Retries
This field sets the number of times that the BMC tries to resend a SOL message to a remote
console.
The number of retries must between 0 and 7.
Retry Interval
This field sets the number of milliseconds that the BMC waits between trying to send SOL
messages to a remote client.
The value entered must be between 0 and 2559. The SMU truncates the digit in the ones column
from any input number because the firmware maintains this value in 10 millisecond intervals.
Therefore, any value that is entered between 0 and 9 is displayed as 0.
Summary of Contents for PowerEdge 7250
Page 9: ...Introduction 7 Figure 1 1 BMC Configuration Matrix ...
Page 37: ...BMC Management Utility 35 Figure 3 3 IPMI Help Option Example 1 ...
Page 58: ...56 BMC Management Utility w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 64: ...62 BMC Management Utility Error Codes w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 70: ...68 Using Console Redirection w w w d e l l c o m s u p p o r t d e l l c o m ...