Figure 78. Installing the heat sink
Next steps
1. If removed,
.
2. Follow the procedure listed in the
After working inside your system
on page 47.
Expansion cards and expansion card risers
NOTE:
A system event entry is logged in the iDRAC Lifecycle Controller if an expansion card riser is not supported or
missing. It does not prevent your system from turning on. However, if a F1/F2 pause occurs with an error message, see
Troubleshooting expansion cards
section in the
Dell EMC PowerEdge Servers Troubleshooting Guide
at
Expansion card installation guidelines
The following table describes the supported expansion cards:
Table 39. Expansion card riser configurations
Expansion card riser
PCIe slots
Processor
connection
Height
Length
Slot
width
Riser 1
Slot 1
Processor 1
Full Height
Half Length
x8
x16
Slot 2
x8
x16
Riser 2
Slot 3
Processor 1
Low Profile
Half Length
x16
Slot 6
Processor 2
Riser 3
Slot 4
Processor 2
Full Height
Half Length
x8
x8
Slot 5
x16
Installing and removing system components