Operation
DeLaval voluntary milking system VMS
94897201.pdf
2007-12-18
teaching window.
Determining the positions of all
teatcups at the same time
Robot teaching window
Note:
Ensure that the station is in manual
mode.
On the touch screen:
1. Set the service switch in service mode.
2. Press the
VMS
button in the top right
corner.
3. Press the
Manual Teach
button.
3. On the VMS menu, press the
Robot
Teaching
button.
4. Press the
Teach All Cup Positions
button.
This will move the arm to an initial position
near the teatcups.
5. Hold the safety button on the joystick and
keep it held during the procedure.
6. Press (and release) the confirm button
OK
on the joystick as the appearing pop-up
window requests.