Troubleshooting
DeLaval voluntary milking system VMS
94897201.pdf
2007-12-18
M
m
Alarm text
Type
Meaning
Action
M
m
Alarm text
Type
Meaning
Action
5
117
Temperature
teat cleaner...
User
notification
If teat cleaning water is above 42
degrees Celsius. @@The current
teat cleaning will be aborted.
If the sensor indicates a rise in temperature
above the limit:
- Check the water temperature.
- Check the temperature sensor.
(A teat cleaning can be started manually
from the touch screen).
Temporary solutions:
The teat cleaning function can be disabled
for each cow in (PC setting). Note,
however, that this might affect the milk
quality. In addition, this measure is not fool
proof. The cause of the high water
temperature must be investigated and the
problem resolved.
The sensor can also be removed. The
system will then generate the message
"Teatcleaner temp sensor malfunction"
(major code 5, minor code 119). See below.
5
117
Temperature
teat cleaner...
User
notification
If teat cleaning water is above 42
degrees Celsius. @@The current
teat cleaning will be aborted.
If the sensor indicates a rise in temperature
above the limit:
- Check the water temperature.
- Check the temperature sensor.
(A teat cleaning can be started manually
from the touch screen).
Temporary solutions:
The teat cleaning function can be disabled
for each cow in (PC setting). Note,
however, that this might affect the milk
quality. In addition, this measure is not fool
proof. The cause of the high water
temperature must be investigated and the
problem resolved.
The sensor can also be removed. The
system will then generate the message
"Teatcleaner temp sensor malfunction"
(major code 5, minor code 119). See below.
5
118
Teatcleaner
too hot...
User
notification
The temperature of the water for
the teat cleaner has exceeded
42deg. System will stop
immidiately.
Note:
There is a risk
for milk contamination if teat
cleaning is not used.
See "Temperature teat cleaner" (major
code 5, Minor code 117) above.
5
118
Teatcleaner
too hot...
User
notification
The temperature of the water for
the teat cleaner has exceeded
42deg. System will stop
immidiately.
Note:
There is a risk
for milk contamination if teat
cleaning is not used.
See "Temperature teat cleaner" (major
code 5, Minor code 117) above.
5
119
Teatcleaner
temp sensor
malfunction
User
notification
The system receives information
that the teat cleaning water is
below zero degrees Celsius. The
temperature sensor is damaged or
not installed.
Check the water temprature.
If installed, check the temperature sensor.
5
119
Teatcleaner
temp sensor
malfunction
User
notification
The system receives information
that the teat cleaning water is
below zero degrees Celsius. The
temperature sensor is damaged or
not installed.
Check the water temprature.
If installed, check the temperature sensor.
5
120
Scheduled
cleaning
NOT done
Deviation
The system was in manual mode
when a scheduled cleaning was
set to take place. (Scheduled
cleanings take place only in
automatic mode.)
Start the cleaning.
5
120
Scheduled
cleaning
NOT done
Deviation
The system was in manual mode
when a scheduled cleaning was
set to take place. (Scheduled
cleanings take place only in
automatic mode.)
Start the cleaning.
5
121
Communicat-
ion lost with
milkroom
controller
Stop alarm
The milking station has lost
communication with the milk room
controller (node E50 on the
ALCOM bus). Possible cause may
be that the bus is drawn incorrectly.
- Check that the ALCOM bus is not broken
or disconnected.
- Check that the bus drawn correctly
between the two units.
5
121
Communicat-
ion lost with
milkroom
controller
Stop alarm
The milking station has lost
communication with the milk room
controller (node E50 on the
ALCOM bus). Possible cause may
be that the bus is drawn incorrectly.
- Check that the ALCOM bus is not broken
or disconnected.
- Check that the bus drawn correctly
between the two units.
5
122
Teatcup not
tight to jetter
Deviation
There is air leakage between one
or several of the liners’ mouthpiece
lips and the sealing collars,
impairing the system’s ability to
draw water from the cleaning unit.
The vacuum level/air flow is
detected by the shut-off valves.
If leakage is detected, the system
makes three attempts to reposition
the teatcups. If this fails, the alarm
message will be issued.
This alarm message will not stop
the cleaning process, but there is a
risk that the air leakage will cause
the cleaning unit to issue a timeout
alarm (major code 7, minor code
4). The timeout alarm will halt the
system.
- Check the length and condition of the milk
tubes. Make sure that the teatcups can be
released onto the jetters and their sealing
collars easily.
5
122
Teatcup not
tight to jetter
Deviation
There is air leakage between one
or several of the liners’ mouthpiece
lips and the sealing collars,
impairing the system’s ability to
draw water from the cleaning unit.
The vacuum level/air flow is
detected by the shut-off valves.
If leakage is detected, the system
makes three attempts to reposition
the teatcups. If this fails, the alarm
message will be issued.
This alarm message will not stop
the cleaning process, but there is a
risk that the air leakage will cause
the cleaning unit to issue a timeout
alarm (major code 7, minor code
4). The timeout alarm will halt the
system.
- Check the length and condition of the milk
tubes. Make sure that the teatcups can be
released onto the jetters and their sealing
collars easily.
183(198)
Summary of Contents for VMS 2008
Page 1: ...Instruction Book DeLaval voluntary milking system VMS model 2008 2007 12 18 0712 94897201 pdf ...
Page 2: ......
Page 10: ...94897201 pdf 2007 12 18 2 198 ...
Page 144: ...Maintenance DeLaval voluntary milking system VMS 94897201 pdf 2007 12 18 136 198 ...
Page 154: ...Maintenance Milk sampler 94897201 pdf 2007 12 18 146 198 ...
Page 193: ...Troubleshooting DeLaval voluntary milking system VMS 94897201 pdf 2007 12 18 185 198 ...
Page 206: ...DeLaval Box 39 SE 147 21 Tumba SWEDEN www delaval com ...