Operation
VMS cleaning
94897201.pdf
2007-12-18
remove.
One way to solve a too low temperature of
the return water may be to raise the start
temperature somewhat. Another may be to
insulate the piping of the system.
Optimal temperature of the pre-rinse water
is 35-45 °C. In this range, milk residues will
be rinsed out of the system. Temperatures
above 50 °C will, on the other hand, cause
the proteins in the milk to denaturate and
precipitate as deposits within the system.
Hot water supply
Make sure there is enough hot water to
clean all subsystems at the same time:
milking station(s), storage tanks, etc.
Bear in mind that some hot water will be lost
due to mixing it with the cold water in the
boiler(s). If the boiler(s) does not produce
enough hot water, a bigger boiler may be
needed.
Always consult your DeLaval service
engineer if you have questions water
temperature, detergents, water temperature,
water supply, etcetera.
Detergents and detergent
dosing
Alkaline dominant cleaning scheme
A phosphated, alkaline detergent such as
DeLaval Ultra can handle water hardness
up to 30 dH. If the hardness is higher than
this, water treatment is necessary.
The table below may serve as a guideline
for an alkaline dominant cleaning strategy.
Note that cleaning too often with acid
detergent will reduce the effectiveness of
the cleaning strategy since the acid
detergent, such as DeLaval Cidmax, is a
descaler and not intended to remove
proteins and fat. Omitting use of alkaline
detergent will therefore cause a build-up of
impurities within the system. As few as two
consecutive cleanings with acid detergent
instead of alkaline might make it necessary
to increase the dosing of the alkaline
97(198)
Summary of Contents for VMS 2008
Page 1: ...Instruction Book DeLaval voluntary milking system VMS model 2008 2007 12 18 0712 94897201 pdf ...
Page 2: ......
Page 10: ...94897201 pdf 2007 12 18 2 198 ...
Page 144: ...Maintenance DeLaval voluntary milking system VMS 94897201 pdf 2007 12 18 136 198 ...
Page 154: ...Maintenance Milk sampler 94897201 pdf 2007 12 18 146 198 ...
Page 193: ...Troubleshooting DeLaval voluntary milking system VMS 94897201 pdf 2007 12 18 185 198 ...
Page 206: ...DeLaval Box 39 SE 147 21 Tumba SWEDEN www delaval com ...