1
111
Cow not
identified
Deviation
The cow has not been identified
within the preset time and will be
released.
If identification fails for all cows, contact
service engineer.
Service engineer only: The time the system
tries to identify a cow can be changed in the
management software (VMS Config).
If the cow(s) for which the identification
failed are known, check the transponder(s):
Remove the transponder from the cow,
press “Accept cow” on the touch screen,
activate the photocell until the entrance
gate is closed, then put the transponder
close to the transponder. The cow number
associated with transponder should now be
shown on the touch screen.
If this alarm appears several times a week,
make sure that the transponder collars are
loose enough for the transponders to hang
vertically from the neck of the cows.
Otherwise, the transponder reader might
have difficulty in reading the transponder
number.
1
111
Cow not
identified
Deviation
The cow has not been identified
within the preset time and will be
released.
If identification fails for all cows, contact
service engineer.
Service engineer only: The time the system
tries to identify a cow can be changed in the
management software (VMS Config).
If the cow(s) for which the identification
failed are known, check the transponder(s):
Remove the transponder from the cow,
press “Accept cow” on the touch screen,
activate the photocell until the entrance
gate is closed, then put the transponder
close to the transponder. The cow number
associated with transponder should now be
shown on the touch screen.
If this alarm appears several times a week,
make sure that the transponder collars are
loose enough for the transponders to hang
vertically from the neck of the cows.
Otherwise, the transponder reader might
have difficulty in reading the transponder
number.
1
112
Unexpected
high yield
Deviation
More milk (50%) than expected
has been obtained from a quarter.
Check the corresponding air-inlet is not
clogged. If the problem persists, contact
service engineer.
1
112
Unexpected
high yield
Deviation
More milk (50%) than expected
has been obtained from a quarter.
Check the corresponding air-inlet is not
clogged. If the problem persists, contact
service engineer.
1
114
Mumgr
disconnected
Stop alarm
The main program in the milking
station is deactivated.
Restart the milking station. If the problem
persists, contact service engineer.
1
114
Mumgr
disconnected
Stop alarm
The main program in the milking
station is deactivated.
Restart the milking station. If the problem
persists, contact service engineer.
1
115
Unexpected
low yield
Deviation
Less than 40% of the expected
yield has been obtained from a
quarter.
Check the cow.
1
115
Unexpected
low yield
Deviation
Less than 40% of the expected
yield has been obtained from a
quarter.
Check the cow.
1
117
High MS
temperature(-
...)
User
notification
Temperature in the system is
above 60 degrees centigrade.The
alarm will call the farmer but
system will remain in auto mode.
Temperature must go below 60
and up again to trigg a new alarm.
Turn on or increase the flow of cooling air to
the electrical cubicle.
1
117
High MS
temperature(-
...)
User
notification
Temperature in the system is
above 60 degrees centigrade.The
alarm will call the farmer but
system will remain in auto mode.
Temperature must go below 60
and up again to trigg a new alarm.
Turn on or increase the flow of cooling air to
the electrical cubicle.
1
119
Not cleaned
after divert
Stop alarm
A rinse or cleaning should have
been carried out after the last
milking, but was not. The selected
milk type for the cow is probably
"Divert milk" after wich normally
should follow a cleaning
procedure. (This milk type is used,
for example, when a cow receives
some kind of medical treatment.)
Start a rinse or cleaning manually.
1
119
Not cleaned
after divert
Stop alarm
A rinse or cleaning should have
been carried out after the last
milking, but was not. The selected
milk type for the cow is probably
"Divert milk" after wich normally
should follow a cleaning
procedure. (This milk type is used,
for example, when a cow receives
some kind of medical treatment.)
Start a rinse or cleaning manually.
1
120
Autocalibrati-
on fails
status ...
Deviation
Autocalibration of the robot has
failed.
Additional information: 20 =
Problem with Balance or PRBS
calibration. 21 = Problem with
performance. 30 = Calibration
cancelled by operator. (Previous
calibration data will be used.)
No action is necessary if the robot performs
well. Inform service engineer if the robot is
not working well.
1
120
Autocalibrati-
on fails
status ...
Deviation
Autocalibration of the robot has
failed.
Additional information: 20 =
Problem with Balance or PRBS
calibration. 21 = Problem with
performance. 30 = Calibration
cancelled by operator. (Previous
calibration data will be used.)
No action is necessary if the robot performs
well. Inform service engineer if the robot is
not working well.
1
121
Guardmaster
block MS
User
notification
US market only. Guardmaster has
been activated and is blocking
movement of robot arm and
magazine.
Clear blocking by entering pin code at
Guardmaster. This will allow normal
operation of milksing station
1
121
Guardmaster
block MS
User
notification
US market only. Guardmaster has
been activated and is blocking
movement of robot arm and
magazine.
Clear blocking by entering pin code at
Guardmaster. This will allow normal
operation of milksing station
1
122
Guardmaster
allow MS
Status
message
US market only. Guardmaster has
granted normal operation of
milking station.
None
1
122
Guardmaster
allow MS
Status
message
US market only. Guardmaster has
granted normal operation of
milking station.
None
158(198)
Summary of Contents for VMS 2008
Page 1: ...Instruction Book DeLaval voluntary milking system VMS model 2008 2007 12 18 0712 94897201 pdf ...
Page 2: ......
Page 10: ...94897201 pdf 2007 12 18 2 198 ...
Page 144: ...Maintenance DeLaval voluntary milking system VMS 94897201 pdf 2007 12 18 136 198 ...
Page 154: ...Maintenance Milk sampler 94897201 pdf 2007 12 18 146 198 ...
Page 193: ...Troubleshooting DeLaval voluntary milking system VMS 94897201 pdf 2007 12 18 185 198 ...
Page 206: ...DeLaval Box 39 SE 147 21 Tumba SWEDEN www delaval com ...