Operation
DeLaval voluntary milking system VMS
94897201.pdf
2007-12-18
————————————————————
Warning:
The Robot Air Lock button does
not deactivate the end effector.
————————————————————
————————————————————
Warning:
The two buttons Main Laser and
Teat Laser in the lower left corner of the
window turn on the lasers. Do not stare into
the laser beam.
————————————————————
Restarting the milking station after a
power failure
When the power comes back, the milking
station will be in stand-by mode. Do the
following to restart the milking system:
1. Press the start button. This will restart the
milking station, then
Waiting for cow
window
will appear on the touch screen.
2. After the restart, the milking station will be
in manual mode (if the default value is set to
manual mode). To switch the milking station
to automatic mode, see the section
“Switching from manual to automatic mode”
above.
Starting the hydraulic pump unit
after oil temperature, oil level or
motor protection alarms
The oil temperature and oil level sensors
triggers an alarm and stops the operation of
the hydraulic pump unit when the oil
temperature is too high (over 60 ºC), the oil
level is too low or the motor protection stops
the motor. Perform the following tasks if any
of these alarms are issued:
Oil temperature alarm
Make sure that the ambient temperature in
the VMS room is below 40 °C. Wait until the
oil temperature of the hydraulic pump unit
drops below 55 °C. The hydraulic pump unit
will then start automatically.
52(198)
Summary of Contents for VMS 2008
Page 1: ...Instruction Book DeLaval voluntary milking system VMS model 2008 2007 12 18 0712 94897201 pdf ...
Page 2: ......
Page 10: ...94897201 pdf 2007 12 18 2 198 ...
Page 144: ...Maintenance DeLaval voluntary milking system VMS 94897201 pdf 2007 12 18 136 198 ...
Page 154: ...Maintenance Milk sampler 94897201 pdf 2007 12 18 146 198 ...
Page 193: ...Troubleshooting DeLaval voluntary milking system VMS 94897201 pdf 2007 12 18 185 198 ...
Page 206: ...DeLaval Box 39 SE 147 21 Tumba SWEDEN www delaval com ...