Troubleshooting
DeLaval voluntary milking system VMS
94897201.pdf
2007-12-18
M
m
Alarm text
Type
Meaning
Action
M
m
Alarm text
Type
Meaning
Action
Service engineer only:
- Put the station in manual mode.
- Check that the tilt function/sensor is
working: on the touch screen, open the
"Robot Service" window, then press the
"Tilt" button. Check that the movements of
the gripper corresponds to your actions
(Out = away from you, In = towards to you).
- Check that the “Cup in gripper” sensor is
working, for example by putting a
screwdriver close to the sensor. Check that
the sensor indicator on the screen (Cup in
gripper) corresponds to your actions.
- If the Cup in gripper sensor is not working,
then it may be disabled in the management
software (VMS Config). This may solve the
problem.
Note: Disabling the Cup in gripper is a
temporary measure. The sensor should be
repaired and enabled as soon as possible.
Service engineer only:
- Put the station in manual mode.
- Check that the tilt function/sensor is
working: on the touch screen, open the
"Robot Service" window, then press the
"Tilt" button. Check that the movements of
the gripper corresponds to your actions
(Out = away from you, In = towards to you).
- Check that the “Cup in gripper” sensor is
working, for example by putting a
screwdriver close to the sensor. Check that
the sensor indicator on the screen (Cup in
gripper) corresponds to your actions.
- If the Cup in gripper sensor is not working,
then it may be disabled in the management
software (VMS Config). This may solve the
problem.
Note: Disabling the Cup in gripper is a
temporary measure. The sensor should be
repaired and enabled as soon as possible.
2
116
Gripper is
not empty
Stop alarm
The robot has released a cup but
still detects an object in the
gripper. The robot will be parked.
- Check if something has got stuck in the
gripper, then try the desired action once
again.
- If the problem persists, call service
engineer.
2
116
Gripper is
not empty
Stop alarm
The robot has released a cup but
still detects an object in the
gripper. The robot will be parked.
- Check if something has got stuck in the
gripper, then try the desired action once
again.
- If the problem persists, call service
engineer.
The system will perform a self-test
while the cow remains inside the
station. If the self-test is
successful, operation continues.
Otherwise, the system will be
stopped and this alarm issued.
Service engineer only:
- Put the station in manual mode.
- On the touch screen, open the "Robot
Service" window.
- Check that the item in gripper
function/sensor is working, for example by
putting a screwdriver close to the sensor.
Check that the sensor indicator on the
screen (Item in gripper) corresponds to your
actions.
- If the Item in gripper sensor is not working,
then it may be disabled in VMS Config. This
may solve the problem.
Note: Disabling the item in gripper sensor is
a temporary measure. The sensor should
be repaired and enabled as soon as
possible.
The system will perform a self-test
while the cow remains inside the
station. If the self-test is
successful, operation continues.
Otherwise, the system will be
stopped and this alarm issued.
Service engineer only:
- Put the station in manual mode.
- On the touch screen, open the "Robot
Service" window.
- Check that the item in gripper
function/sensor is working, for example by
putting a screwdriver close to the sensor.
Check that the sensor indicator on the
screen (Item in gripper) corresponds to your
actions.
- If the Item in gripper sensor is not working,
then it may be disabled in VMS Config. This
may solve the problem.
Note: Disabling the item in gripper sensor is
a temporary measure. The sensor should
be repaired and enabled as soon as
possible.
2
123
Robot needs
air to stall
Stop alarm
The tilt or grip movement failed
because the compressed air to the
milking station has probably been
switched off.
Compressed air is used by the
gates, the feeding module, the rear
plate and the tilt and grip functions.
This error should never occur in automatic
mode.
Press the "Save Logfiles" button on the
touch screen as soon as possible after the
error occurred ("Miscellaneous Service"
window). Notify the service engineer.
Service engineer only:
If the main air supply to the station has
been switched off (main valve in the upper
beam has been closed), then switch it on
again.
- If the air has not been switched off, call
Help desk in Tumba.
2
123
Robot needs
air to stall
Stop alarm
The tilt or grip movement failed
because the compressed air to the
milking station has probably been
switched off.
Compressed air is used by the
gates, the feeding module, the rear
plate and the tilt and grip functions.
This error should never occur in automatic
mode.
Press the "Save Logfiles" button on the
touch screen as soon as possible after the
error occurred ("Miscellaneous Service"
window). Notify the service engineer.
Service engineer only:
If the main air supply to the station has
been switched off (main valve in the upper
beam has been closed), then switch it on
again.
- If the air has not been switched off, call
Help desk in Tumba.
166(198)
Summary of Contents for VMS 2008
Page 1: ...Instruction Book DeLaval voluntary milking system VMS model 2008 2007 12 18 0712 94897201 pdf ...
Page 2: ......
Page 10: ...94897201 pdf 2007 12 18 2 198 ...
Page 144: ...Maintenance DeLaval voluntary milking system VMS 94897201 pdf 2007 12 18 136 198 ...
Page 154: ...Maintenance Milk sampler 94897201 pdf 2007 12 18 146 198 ...
Page 193: ...Troubleshooting DeLaval voluntary milking system VMS 94897201 pdf 2007 12 18 185 198 ...
Page 206: ...DeLaval Box 39 SE 147 21 Tumba SWEDEN www delaval com ...