The unit can automatically transmit an e-mail to an SMTP Server under numerous conditions i.e. on
start up, on receipt of an alarm, camera failure etc. This allows the unit to be installed in unmanned
applications where a Remote Video Response Centre (or Manager etc.) would be notified by e-mail
if any of these conditions occur.
Connection Profile
It is possible for the e-mail to be transmitted via the Ethernet
network or dial up connection (PPP ‘Point to Point Protocol’).
This setting presumes that a modem has been connected or
configured and the unit is connected to a LAN or WAN and
allocated a valid IP address.
Mail Server Address
This is the IP address or URL of the SMTP Server that the e-mail
will be sent to. The SMTP server will then forward this to the
intended recipient.
Recipient Email
This is the e-mail address of the intended recipient.
Recipient Display Name
This is the addressee name that will be shown in the email name
field.
Reply to Email
This field must be configured if the recipient is to reply to an e-
mail. The unit does not accept incoming e-mails therefore ensure
this is a valid e-mail address.
Reply To Display Name
This is the ‘reply to’ name that will be shown in the email
name field.
Sender Email
These optional fields indicate the source of the e-mail notification.
If the fields are left blank the unit will use the system name to
create a sender name.