DW1000 User Manual
© Decawave Ltd 2017
Version 2.12
Page 117 of 242
Sub-Index
Field
Description of fields within Register file: 0x21 – User defined SFD
17
reg:21:11
TX_LSFD_SGN0
(Symbols 7..0)
This field sets the long (64-symbol) SFD polarity data for the transmitted SFD
sequence. This byte covers the first 8 symbol intervals, symbols 7 to 0. The low
order bits define the part of the SFD sequence sent first in time.
18
reg:21:12
TX_LSFD_SGN1
(Symbols 15..8)
This field sets the long (64-symbol) SFD polarity data for the transmitted SFD
sequence, for symbol intervals 15 to 8.
19
reg:21:13
TX_LSFD_SGN2
(Symbols 23..16)
This field sets the long (64-symbol) SFD polarity data for the transmitted SFD
sequence, for symbol intervals 23 to 16.
20
reg:21:14
TX_LSFD_SGN3
(Symbols 31..24)
This field sets the long (64-symbol) SFD polarity data for the transmitted SFD
sequence, for symbol intervals 31 to 24.
21
reg:21:15
TX_LSFD_SGN4
(Symbols 39..32)
This field sets the long (64-symbol) SFD polarity data for the transmitted SFD
sequence, for symbol intervals 39 to 32.
22
reg:21:16
TX_LSFD_SGN5
(Symbols 47..40)
This field sets the long (64-symbol) SFD polarity data for the transmitted SFD
sequence, for symbol intervals 47 to 40.
23
reg:21:17
TX_LSFD_SGN6
(Symbols 55..48)
This field sets the long (64-symbol) SFD polarity data for the transmitted SFD
sequence, for symbol intervals 55 to 48.
24
reg:21:18
TX_LSFD_SGN7
(Symbols 63..56)
This field sets the long (64-symbol) SFD polarity data for the transmitted SFD
sequence, for symbol intervals 63 to 56.
25
reg:21:19
RX_LSFD_MAG0
(Symbols 7..0)
This field sets the long (64-symbol) SFD magnitude data for the receive SFD
sequence. This byte covers the first 8 symbol intervals, symbols 7 to 0. The low
order bits define the part of the SFD sequence arriving first in time.
26
reg:21:1A
RX_LSFD_MAG1
(Symbols 15..8)
This field sets the long (64-symbol) SFD magnitude data for the receive SFD
sequence, for symbol intervals 15 to 8.
27
reg:21:1B
RX_LSFD_MAG2
(Symbols 23..16)
This field sets the long (64-symbol) SFD magnitude data for the receive SFD
sequence, for symbol intervals 23 to 16.
28
reg:21:1C
RX_LSFD_MAG3
(Symbols 31..24)
This field sets the long (64-symbol) SFD magnitude data for the receive SFD
sequence, for symbol intervals 31 to 24.
29
reg:21:1D
RX_LSFD_MAG4
(Symbols 39..32)
This field sets the long (64-symbol) SFD magnitude data for the receive SFD
sequence, for symbol intervals 39 to 32.
30
reg:21:1E
RX_LSFD_MAG5
(Symbols 47..40)
This field sets the long (64-symbol) SFD magnitude data for the receive SFD
sequence, for symbol intervals 47 to 40.
31
reg:21:1F
RX_LSFD_MAG6
(Symbols 55..48)
This field sets the long (64-symbol) SFD magnitude data for the receive SFD
sequence, for symbol intervals 55 to 48.
32
reg:21:20
RX_LSFD_MAG7
(Symbols 63..56)
This field sets the long (64-symbol) SFD magnitude data for the receive SFD
sequence, for symbol intervals 63 to 56.
33
reg:21:21
RX_LSFD_SGN0
(Symbols 7..0)
This field sets the long (64-symbol) SFD polarity data for the receive SFD
sequence. This byte covers the first 8 symbol intervals, symbols 7 to 0. The low
order bits define the part of the SFD sequence arriving first in time.
34
reg:21:22
RX_LSFD_SGN1
(Symbols 15..8)
This field sets the long (64-symbol) SFD polarity data for the receive SFD
sequence, for symbol intervals 15 to 8.
35
reg:21:23
RX_LSFD_SGN2
(Symbols 23..16)
This field sets the long (64-symbol) SFD polarity data for the receive SFD
sequence, for symbol intervals 23 to 16.
36
reg:21:24
RX_LSFD_SGN3
(Symbols 31..24)
This field sets the long (64-symbol) SFD polarity data for the receive SFD
sequence, for symbol intervals 31 to 24.
37
reg:21:25
RX_LSFD_SGN4
(Symbols 39..32)
This field sets the long (64-symbol) SFD polarity data for the receive SFD
sequence, for symbol intervals 39 to 32.
38
reg:21:26
RX_LSFD_SGN5
(Symbols 47..40)
This field sets the long (64-symbol) SFD polarity data for the receive SFD
sequence, for symbol intervals 47 to 40.
39
reg:21:27
RX_LSFD_SGN6
(Symbols 55..48)
This field sets the long (64-symbol) SFD polarity data for the transmitted SFD
sequence, for symbol intervals 55 to 48. Receive
40
reg:21:28
RX_LSFD_SGN7
(Symbols 63..56)
This field sets the long (64-symbol) SFD polarity data for the receive SFD
sequence, for symbol intervals 63 to 56.