Installing the Mounting Panel
The panel is mounted to the struts via holes in the four corners of the panel. The mounting panel can be
bolted directly to a wall, but it is usually more convenient to mount struts to the wall and then mount
the control panel to the strut.
Attach the mounting plate by inserting four 3/8” – 16 x 1-1/2” long bolts and lock washers. Tighten the
bolts so that the control panel is adequately supported.
Note: Do not connect power to the mounting plate until installation is complete.
Cell Installation
Remove the cell from its packaging and place it vertically into the cell support bracket on the mounting
panel. Refer to Figure 3 for orientation of cell placement in the support bracket.
Connect the cell electrical leads, matching the red lead to the anode side of the cell (the side facing the
panel), and the black lead to the cathode side of the side of the cell (the side facing the operator). Check
and tighten the ¼ - 20 cell lead/lug flange nuts to 100 inch-lbs. (11.3 N-m) torque.
NOTE: To ensure a good electrical connection, do not use washers. The nuts provided with
integral serrated flange will provide a good connection. Electrical conductive grease, should