FCC Part 15 Regulatory Statement 

 
This equipment has been tested and found to comply with the limits for Class A digital device pursuant 
to  Part  15  of  the  FCC  Rules.  These  limits  are  designed  to  provide  reasonable  protection  against 
harmful  interference  when  the  equipment  is  operated  in  a  commercial  environment.  This  equipment 
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance 
with  the  instruction's  manual,  may  cause  interference  to  radio  communications.  Operation  of  this 
equipment in a residential area is likely to cause interference in which case the user will be required to 
correct  the  interference  at  their  own  expense.  The  user  is  cautioned  that  changes  and  modifications 
made to the equipment without approval of the manufacturer could void the user's authority to operate 
this  equipment.  The  user  should  use  only  shielded  and/or  grounded  cables  to  combat  sources  of 
interference. 
 

Environmental Preservation Efforts 

 

This equipment has been designed and built by DaySequerra corporation to give many 
years of trouble free service and is backed by our three year warranty and commitment 
of  providing  the  best  customer  support.  When  the  time  comes  to  retire  your  product 
from service, it should be disposed of in accordance with local codes or ordinances. Do 
not discard with household or commercial waste. 
 
 
DaySequerra products are manufactured with the environment in mind. 

The directive on the restriction of the use of certain hazardous substances in electrical 
and  electronic  equipment  (2002/95/EC)  restricts  the  use  of  six  specific  hazardous 
materials  in  the  manufacture  of  various  types  of  electronic  and  electrical  equipment. 
Following this directive prevents these toxic substances from entering our environment 
after disposal. 
 

Summary of Contents for MultiMerge2

Page 1: ...MultiMerge2 NLC 5 1 SurroundAudio Processor User Manual...

Page 2: ...e MultiMerge2 and all of our products has evolved through a process of user feedback extensive listening field testing and careful refinement In the event that you encounter any technical or operation...

Page 3: ...s subject to change MultiMerge2 Revision A MultiMerge2 Key Features Simultaneous processing for 5 1 main and 2 0 auxiliary stereo inputs and loudness control signal flows UpMix HD algorithm for near d...

Page 4: ...actory contact us for a return authorization number Please visit www daysequerra com and register your new MultiMerge2 so we can keep you informed of the latest hardware and software updates The light...

Page 5: ...LATENCY 38ms UpMix HD High Latency 0ms Lt Rt DownMix 48ms DTS Neural Loudness Control 6ms for Hardware Interface GPIO Opto isolated DB 9 female connector 0 5VDC TTL ETHERNET 10 100 Base T for field so...

Page 6: ...facturer could void the user s authority to operate this equipment The user should use only shielded and or grounded cables to combat sources of interference Environmental Preservation Efforts This eq...

Page 7: ...udness leveling algorithm to apply the appropriate gain or attenuation to maintain the broadcaster defined loudness level The resulting audio has a naturally open dynamic quality without the annoying...

Page 8: ...llation The MultiMerge2 chassis has four rack mounting holes and has been designed to fit in a standard 1RU space Plastic finishing washers are recommended to protect the painted surface around the mo...

Page 9: ...9 MultiMerge2 User Manual Menu Tree Figure 1 MultiMerge2 Menu Tree...

Page 10: ...ION KNOB A stepping rotational knob is used to select values while in the menu system To enter the menu simply rotate the knob in any direction while MultiMerge2 is on the HOME screen ENTER KEY Used t...

Page 11: ...S Input 8 OUTPUT LEVELS LED display shows current amplitude of output signal from 60dB to 0dB across all active channels Unused channels will not light the display L Left AES Input 1 Ls Left Surround...

Page 12: ...enters home screen selection mode that allows quick access to key functions 1 Measured Short Term Combined Average of 5 1 Surround 2 Read Only 5 1 Surround preset indicator 3 Selected Neural Loudness...

Page 13: ...an AES REF or DARS clock signal from an external source and pass it on to other devices The AES 3id 1995 SMPTE 276M standard dictates a 75 unbalanced connection and requires proper termination The ter...

Page 14: ...or hub a crossover cable is required Firmware updating is accomplished via UDP Port 44600 Please refer to the MultiMerge2 Firmware Update section of this manual for more details the update procedure P...

Page 15: ...revious menu level or revert the current value to its last stored state System Menu Function and Description Figure 6 System Menu Screen Display From the Home Screen press ENTER to enter the System Me...

Page 16: ...High and Low Latency are available High Latency UpMix Algorithm provides a near discrete 5 1 performance from Stereo 5 1 Final Limiter A final limiter is present to control the absolute waveform peak...

Page 17: ...erge2 is configured to take a DHCP address by default Device Name Allows you to change MultiMerge2 s name as reported to DNS Press ENTER while the cursor is over this field to go into data entry mode...

Page 18: ...udio in UpMix Meter Brightness Allows adjustment of MultiMerge2 s Input and Output meters Display Brightness Allows adjustment of MultiMerge2 s display output Restore Settings Returns all settings to...

Page 19: ...eylock altogether After the user specified period of inactivity the keylock will automatically enable Default 15 min Figure 13 Keylock on Multimerge 2 About Menu Model Number Displays the model number...

Page 20: ...om the stereo mix 0 00 1 00 in 05 Increments UpMix LFE Cutoff defines how MultiMerge 2 s UpMix functionality will treat low frequency effects Normal or Mute DownMix LFE Cutoff defines how MultiMerge 2...

Page 21: ...dary Compressor is set further away from the Target as to allow more transients The goal of this preset is to fine tune long term loudness levels while preserving a majority of the original signal s d...

Page 22: ...ove the Target Level the input signal can range before attenuation is applied If an input signal falls between the Upper Thresh and the Lower Thresh in reference to the Target Level no correction will...

Page 23: ...loudness level Frequency Shaping Loudness studies dating have found that the human ear is more sensitive to different frequencies at different loudness levels Frequency Shaping accounts for these dif...

Page 24: ...stream Check that equipment up stream of MultiMerge2 is properly configured to output the correct audio stream Validity Error MultiMerge2 has encountered a validity error with the audio stream Check...

Page 25: ...eps to upgrade your unit 1 Un Zip the files using a compatible utility that can handle ZIP archive file format into a new empty directory on your PC 2 Disable any additional network interface adapters...

Page 26: ...the customer accordingly DaySequerra reserves the right to replace any product that has been discontinued from its product line with a new product of comparable value and function This warranty shall...

Page 27: ...ge2 User Manual Manufactured under license from DTS Licensing Limited DTS and the Symbol are registered trademarks and the DTS logo is a trademark of DTS Inc Product includes software DTS Inc All Righ...

Reviews: