CAUTION
All these require special tools and skills. Do not perform the
injection nozzle test near an open re or any other kind of re.
The fuel spray may ignite. Do not expose bare skin to the fuel
spray as it may penetrate the skin and cause bodily injury.
Checking and replenishing battery uid
This diesel engine uses a 12V battery. The battery fluid will be lost through continuous
charging and discharging.
Before starting, check for physical damage to the battery and also the electrolyte level and
replenish with distilled water up to the upper mark if necessary. When actual damage is
discovered, replace the battery.
Maintenance for a long time storage
If the generator should be stored for a long time, the following preparation should be
made.
Ÿ
Operate the diesel engine about 3 minutes and stop it.
Ÿ
Stop the diesel engine when still hot, drain old lubricate engine oil and refill with new
one.
Ÿ
Pull out the plug at the cover of diesel engine and add 2ml of lubricate in cylinder and
replace the plug to its original place
Ÿ
For Manual Start, press the decompression lever (non compression position), pull the
recoil handle 2-3 times. (Don’t start diesel engine).
Ÿ
For Electric Start, with the decompression lever in non-compression position, operate
the diesel engine for 2-3 seconds. When the switch is in the start position, don’t start
the diesel engine.
Ÿ
Release the decompression lever and pull the recoil starter slowly, until there is
resistance and stop pulling. (At this time the intake and exhaust valve is at the status of
close, it is suitable to prevent from rust).
Ÿ
Clean and store it in a dry place.