17
Ÿ
Slowly pull out the recoil handle until pressure is felt (that is, to the point in the
compression stroke where the intake and exhaust valves are closed), and leave the
handle in this position. This prevents rust from forming while the engine is not in use.
CAUTION
If the engine keeps on running even after the control lever is
locked at the ‘STOP’ position, turn the fuel oil cock to the
‘CLOSE’ position to stop the engine. Do not stop the engine with
the decompression lever.
Ÿ
Periodic check and maintenance are very important for keeping the engine in good
condition.
Ÿ
The generator consists of diesel engine, alternator, control box and frame etc.
Ÿ
Shut off the engine before performing any maintenance. If the engine must run make
sure the area is well ventilated. The exhaust contains poisonous carbon monoxide
gas.
Ÿ
After engine has been used, clean it immediately with a cloth to prevent corrosion and
to remove sediment.
4. MAINTENANCE
Item
Daily
Check
(1st time)
(2nd and
thereafter)
(Clean)
(Clean)
(Replace if
necessary)
(Replace)
(Replace)
(Replace)
Tighten
head bolts
(1st time)
Service more frequently when
used in dusty areas
First month
or 20hrs
Every 3months
or 100hrs
Service Period
regular
Check and replenish fuel
Drain Fuel Tank
Check and replenish lube
oil
Check for oil leakage
Check and tighten each
parts engine
Change lube oil
Clean oil lter
Air cleaner element
replacement
Clean fuel lter
Check fuel injection pump
Check fuel injection nozzle
Check fuel pipe
Adjust valve clearance for
intake and exhaust valves
Lap intake and exhaust
valves
Replace piston rings
Check battery uid
Every 6months
or 300hrs
Every year or
1000hrs
Summary of Contents for DGW 200P