![DAYLIFF DGW 200P Installation & Operating Manual Download Page 23](http://html1.mh-extra.com/html/dayliff/dgw-200p/dgw-200p_installation-and-operating-manual_3922795023.webp)
20
5. TROUBLE SHOOTING
Problem
Possible Cause
Solution
T h e d i e s e l
engine does
not start
Fuel oil is not enough
Add fuel oil
The switch is not at ‘ON’
position
Turn it to ‘ON’ position
The high pressure pump and
oil nozzle can not inject oil or
the oil amount is not enough
Remove the oil nozzle out and
repair it at test table
The control lever of speed is
not at ‘RUN’ position
Put the control level to ‘RUN’
position
Check the level of lubricant
The specified oil level should
be between upper level ‘H’
and lower level ‘L’
The speed and force to pull
the recoil starter
S t a r t t h e d i e s e l e n g i n e
a c c o r d i n g t o t h e
requirements of operating
procedure of start
The oil nozzle is dirty
Clean the oil nozzle
The battery has no charge
Charge it or replace it with a
new one
The generator
not working
Main switch is not closed
Put the main switch to the ‘ON’
position
The contact os socket is faulty
Repair or replace
The rated speed of generator
cannot be reached
Adjust it according to the
requirement
Summary of Contents for DGW 200P
Page 1: ...DGW Installation Operating Manual Welding Generator...
Page 2: ......
Page 26: ......
Page 27: ......
Page 28: ...INS302H 11 22...