Calibrate Humidity Setting for Duplex
Range: [-128 to +127/0/1/0.1%]
2. [Clear Modes]> [1] [0] [7]> [Clear/Stop]
SYSTEM Ver. 0.51
Service Menu
3. [
] or [
] > "Engine Maint."> [Yes]
SP No.
1000
4. [Yes] to enter "1" at the first digit and move the cursor to the 2nd digit.
5. [Yes] x1 time> "1100"> [Yes] to enter "1" at the 2nd digit and move the cursor to the 3rd digit.
6. [Yes] x6 times> "1160"> [Yes] to enter "6" at the 3rd digit and move the cursor to the 4th digit.
7. [Yes] x4 times> "1164"> [Yes].
CHG:HUMI:B
1164
8. [Yes]
CHG:HUMI:B
_000
• The first digit is blank. This is the digit for the sign (plus or minus).
• When this digit is empty, the value is set for plus (+) but the plus sign is not displayed.
9. [
] or [
] > "-000" > [Yes] > Cursor moves to 1st zero
CHG:HUMI:B
-000
10. [Yes]> "-000"> To enter the first "0", cursor moves to 2nd "0".
11. [Yes] x2 times> "-020"> [Yes] To enter "2" at the 2nd zero, cursor moves to 3rd "0".
12. [Yes] x5 times> "-025"> [Yes]
CHG:HUMI:B
-025
5. Service Tables
202
5
Summary of Contents for Toscana-C1b
Page 1: ...Toscana C1a C1b C1bN Machine Code J012 J013 J014 SERVICE MANUAL July 2007 Subject to change...
Page 25: ...24...
Page 63: ...1 Installation 62 1...
Page 158: ...Self Diagnostic Test Flow Self Diagnostic Test Flow 157 4...
Page 159: ...4 Troubleshooting 158 4...
Page 160: ...Self Diagnostic Test Flow 159 4...
Page 199: ...4 Troubleshooting 198 4...
Page 330: ...Basic Operation Initialization Sequence at Power On Basic Operation 329 6...
Page 340: ...3 Original Feed Motor 4 Pick up Roller ADF 339 6...
Page 341: ...6 Detailed Section Descriptions 340 6...
Page 364: ...MEMO 363...
Page 365: ...MEMO 364...