1. While holding the plate at about a 30 degree angle, set the left tabs [1] in the holes.
2. Lower the original pressure plate and set center tabs [2].
3. Use a flat-head screwdriver to set right tabs [3].
Scanner to Full Upright
Preparation
• Remove platen (J012) or ADF (J013/J014).
1. Pull forward the release lever under the operation panel [1] and raise the scanner unit.
2. Disconnect the right hinge [2] (
x2).
3. Disconnect the left hinge [1] (
x2).
4. Raise the scanner unit [2] to the full upright position.
• Do not remove the stopper belt [3].
3. Replacement and Adjustment