7. Web Setup
iBoot-G2+ setup section consists of several pages. Access any page via the buttons on the left of the page.
Each time a setting is changed click on the Save button for that page to save the changes before moving to the
next page.
7.1.
Device Settings
Location ID: Set a 20 character name to be
displayed on the top of the home page. This
assists in identifying which iBoot-G2+ is being
accessed. This name is used for LLMNR. see
Local Link Multicast Name Resolution (LLMNR)
section 7.15
. The name is also transmitted to the
cloud on registration to a cloud account. see iBoot
Cloud Service
section 8
.
Delay Time: 0 to 999 seconds delay time. When
powering up multiple devices, a delay can be set
between each outlet.
Outlet Name: Set an independant 20 character
name to be displayed for each of the Main, Exp1
and Exp2 Outlets.
Cycle Time: 0 to 999 seconds power cycle time. This is the length of time the power will be off during a
reboot, or on during a power burst. Unique cycle times can be set for Main, Exp1 and Exp2.
Initial State: Each outlet can be set to the state it will assume when the iBoot-G2+ is powered up or reset
.
The
choices are: On, Off and Last, meaning the state it was in when the power was removed or reset commenced.
Upgrade Enable: Check this box to allow remote firmware upgrades of the iBoot-G2+. When this box is
unchecked, firmware upgrades will not be allowed. When checked, upgrade must occur within 2 minutes of
power up or after a reboot is complete.
Auto Logout: This setting sets the automatic logout for inactivity on both the web and telnet users. It can be
set from 0 to 99 minutes. 0 disables the Auto Logout feature.
As the iBoot-G2+ allows only one Web user logged in at any time, use caution when disabling the
timeout feature, as it is possible to lock out other users by forgetting to logout. Closing the browser
will not log the user out and will lock out web access. If you do become locked out, access the iBoot-
G2+ via Telnet and reboot the unit, or press the reset button.
7.2.
Expansion Settings
Mode: The iBoot-G2+ has three modes of operation for the expansion, each with its own set of settings.
iBoot Expansion Units: For use with the iBoot-EXP expansion units.
Independent I/O: Inputs and outputs are used as status and control not associated with power outlets.
Power Control: For use with external switches to provide manual power control.
Features are dependent on which mode is selected