W-Class
63
Advanced Entry Calibration (continued)
Step
Operator Action
Displayed Message
Comment
13
Using the
key,
select the Gain Number
determined in Step 12.
Press the
key to
select the setting.
GAIN TRAN <yyy>
*08 (0 - 31)
Or, for reflective media:
GAIN REFL <yyy>
*08 (0 - 31)
Selection is
denoted with an
‘*’.
14
å
Place the media in the
Media Sensor. Record
the sensor reading and
label it ‘P’ (paper).
Place the backing, mark,
or notch in the Media
Sensor. Record the
sensor reading and label
it ‘G’ or ‘M’ (Gap or
Mark).
ê
Remove all media.
Record the sensor
reading and label it ‘E’
(Empty).
GAIN TRAN <yyy>
*08 (0 - 31)
Or, for reflective media:
GAIN REFL <yyy>
*08 (0 - 31)
Where ‘yyy’ is
a numerical
value
representing the
current sensor
reading.
15
Press the key.
Then press the
key.
ADVANCED ENTRY
SENSOR LEVELS
The sensor
readings must
be manually
entered into the
printer now.