I-Class
Printer Options (continued)
Menu Item
Details
KILL CODE
Code to permanently deactivate the tag, where:
00 00 00 00
Is the code, in the form B3, B2, B1, B0.
ACCESS CODE
Code to protect tag memory contents, where:
00 00 00 00
Is the code, in the form B3, B2, B1, B0.
GEN 2 LOCK ACTION
Sets the lock for Gen 2 tags, where:
NONE
Does not lock the tag.
PERMALOCK
Locks data permanently.
PWD-READ/WRITE
Locks data with password-protection for writing data.
BOTH
Allows both Permalock and PWD-Lock to be used.
PAD/TRUNC. EPC DATA
Allows padding or truncating of data with nulls
(represented as “00”) in order to fit the selected EPC
Tag Data Size, where:
DISABLED
Does not pad or truncate data.
LEADING
Adds nulls to the front (left) of the data if less than the
size, or cuts the data if greater.
TRAILING
Adds nulls to the end (right) of the data if less than the
size, or cuts the data if greater.
LOCK CODE (ALIEN HW)
Sets the lock code for Alien Gen 2 tags, where:
00 (HEX)
Is the code (00 - FF).
LOCK AFTER WRITE
Locks the tag after programming, where:
DISABLED
No lock occurs.
ENABLED
Locks the tag.