USER INTERFACE AND DIAGNOSTICS
78 SG4 EXTENDED
FAILURE
INFORMATION
FAILURE ON
OSSD
Activate RESET line. If error
persists, contact Datalogic
Technical Support
FAILURE ON
MICROPROCES-
SOR
Activate RESET line. If error
persists, contact Datalogic
Technical Support
FAILURE ON
OPTICS
Activate RESET line. If error
persists, contact Datalogic
Technical Support
FAILURE ON EDM
Check EDM feedback line and
EDM configuration. Activate
RESET line
FAILURE ON
RESTART
Check RESART line connec-
tion. Activate RESET line
COMMUNICATION
FAILURE
(SG4-P only)
Check cascade connection and
correct mounting of termina-
tor cap. Activate RESET line
BCM
COMMUNICATION
FAILURE
Re-operate Basic configura-
tion. If error persists, contact
Datalogic Technical Support
ACM
CONFIGURATION
FAILURE
(SG4-P only)
ration. If error persists, contact
version of the GUI available on
CRITICAL
FAILURE
Turn ON/OFF ESPE. If error
persists, contact Datalogic
Technical Support
POWER SUPPLY
FAILURE
Check power supply connec-
tion. If error persists, contact
Datalogic Technical Support
NOTE
ESPE
WORKING
MODE
INDICATION
LED CONFIGURATION
RECOMMENDATIONS
A critical failure can't be re-established with a Reset procedure but it's
necessary to switch-off and switch-on the light curtain; if the failure per-
sists, please contact the DATALOGIC Technical Support.