FUNCTIONS
42 SG4 EXTENDED
Figure 3 - SG4-N Restart timings (manual)
In Manual Restart the RESTART input (pin 3 of M12-12 poles or pin 1 of M12 8 poles - RX
side) has to be connected to 24VDC through a normally- open contact for SG4-P models
or a normally closed contact on SG4-N models. Please refer to paragraph 8.4 EDM for
RESTART input connection when used in combination with EDM function SG4-…-N mod-
els.
SG4-...-P Restart Connection (manual)
SG4-...-N Restart Connection (manual)
CAUTION
Carefully assess risk conditions and reset modes. In applications protect-
ing access to dangerous areas, the automatic reset mode is potentially
unsafe if it allows the operator to pass completely beyond the sensitive
area.
In this case, the manual reset or, for example, the manual reset of the SE-
SR2 relay (see "
) is necessary.