
MUTING
INSTRUCTION MANUAL 53
Figure 24 - BCM Configuration: Muting Direction
Figure 25 - ACM Configuration: Muting direction
Muting timeout
Muting timeout is a time that defines the maximum duration of Muting function; after
the timeout the Muting ends.
This time can be set from the user in both BCM and ACM mode.
In BCM mode the user can select a timeout of 10 minutes or infinite; “infinite” means
that Muting timeout could never end: if the conditions of Muting persist, the Muting
function continues to exist.
This is not compliant with the EN 61496-1: 2013 standard, and the user is warned about
it.
Figure 26 - Muting timeout
In ACM mode, the user can personalize the timeout from 10 minutes to 1080 minutes
(that correspond to 18 hours) with steps of 1 minute; the user can even set infinite tim-
eout.
Summary of Contents for SG4 FIELDBUS Series
Page 1: ...SG4 Extended INSTRUCTION MANUAL Safety Light Curtains ...
Page 8: ...VIII SG4 EXTENDED COMPLIANCE ...
Page 10: ...X SG4 EXTENDED GENERAL VIEW Figure 1 Safety Light Curtain ...
Page 133: ......
Page 134: ......
Page 135: ......