OVERRIDE FOR SG4-N
INSTRUCTION MANUAL 69
Figure 54 - Dimension tolerance
Blanking in Basic Configuration Mode
In basic configuration mode only a reduced set of possible blanking configuration is pos-
sible.
Figure 55 - BCM Configuration: Fixed Blanking
1 Fixed Blanking zone: only 1 zone can be configured as blanking zone.
2 Fixed Blanking zones: 2 zones can be configured as blanking zone.
Figure 56 - BCM Configuration: Floating Blanking
Floating blanking disabled: no Floating Blanking allowed.
Floating Blanking 1 beam: ESPE stays in NORMAL OPERATION if 1 or 0 beams are inter-
cepted.
Floating Blanking 2 beams: ESPE stays in NORMAL OPERATION if 2 adjacent, 1 or 0
beams are intercepted.
Reduced Resolution 4: ESPE goes in SAFE state if more than 4 adjacent beams gets inter-
cepted.