RESET
active on high level in failure lockout
RESTART
active on high level at runtime
ALIGNMENT
active on high level at startup
OVERRIDE
active on high level at runtime
OVERRIDE 2
active on low level at runtime
EDM
must be OSSDs antivalent at runtime with
EDM enabled
MUTING DISABLE
Muting disabled on high level at runtime
OSSD 1 /
OSSD 2
high level = free path
low level = object detection
OVERRIDE
STATUS
high level = override function active
low level = override function not active
NB: at start-up there are fluctuations on
this line not concerning the override acti-
vation
MUTING LAMP
open collector sinks on Muting activation
MUTING 1 / MUT-
ING 2
active on high level at runtime
EARTH
connect directly to earth
ELECTRICAL CONNECTIONS
24 SG4 EXTENDED
MUTING CONFIGURATION RECEIVER SG4-P
LINE
LAYOUT
CONNECTION
BEHAVIOR