BASIC CONFIGURATION MODE
INSTRUCTION MANUAL 33
BASIC CONFIGURATION MODE
A user interface of 8 LEDs and 3 protected push buttons lets the user operate basic con-
figuration.
LEDs are the same used for user interface in normal operation.
The user must use the provided special tool (see "
Included Accessories" on page 90
), to
activate push buttons thus accidental access to safety configuration is avoided.
Figure 1 - User interface
Basic configuration steps:
In the right side of user control panel (on both units of the light curtain) a setting inter-
face composed by 3 push buttons is present; the purpose of the interface is to let the
user set light curtain locally and without use of PC graphic user interface.
Setting interface is composed by a CONFIRM push button used to enter in BCM and to
confirm the selected configuration, a SELECT push button used to roll by different func-
tions and an ENABLE push button to activate/deactivate the current function.
Here below the necessary steps for BCM configuration:
1. Keep CONFIRM button pressed for 5 seconds to enter Basic Configuration Mode
2. A Test Pattern is shown on led interface; carefully check that ALL LED are lit in
sequence from 2 to 8, then current configuration is shown
3. Choose function to set by SELECT button; selected LED blinks
4. Configure selected function with ENABLE button (switch LED ON/OFF)
5. Repeat steps 3 and 4 until desired configuration is visualized
6. Keep CONFIRM button pressed to authorize the new configuration
If an Advanced Configuration is already set on ESPE (configuration by SG Extended GUI
PC User Interface), a button pressure on Step 2 causes ESPE configuration failure lockout
to prevent unauthorized advanced configuration changes.
CAUTION
Do not use screwdrivers to activate push buttons!