OVERRIDE FOR SG4-N
INSTRUCTION MANUAL 71
Fixed Blanking
The panel on the right shows the settings of the active blanking zone (in the example
here below the active blanking zone has a dimension of 3 beams and is 7 beams from
the bottom of the light curtain; no tolerance is set).
Figure 58 - Fixed Blanking
Fixed Blanking with Increased Tolerance (TOP or BOTTOM)
The example below shows a setting with fixed blanking with increased tolerance top:
over this zone fixed blanking zones only are allowed; under this zone fixed and total sur-
veillance blanking zones are allowed.
Figure 59 - Fixed Blanking with increase tolerance