Caution
SG-ONE is designed for installation within an enclosure. Do not install SG-ONE outside an
enclosure. Install SG-ONE in enclosure rated IP54 or higher.
Install SG-ONE in environments described in the catalog, instruction sheet, and user’s manual. If
SG-ONE is used in places where the SG-ONE is subjected to high temperature, high humidity,
condensation, corrosive gases, excessive vibrations, and excessive shocks then electrical shocks,
fire hazard, or malfunction may result.
Environment for using the SG-ONE is “Pollution degree 2”. Use SG-ONE in environments of
pollution degree 2 (according to IEC/EN60664-1).
Prevent SG-ONE from falling while moving or transporting of the SG-ONE, otherwise damage or
malfunction of the SG-ONE may result.
Prevent metal fragments and pieces of wire from dropping inside the SG-ONE housing. Put a
cover on the SG-ONE during installation and wiring. Ingress of such fragments and chips may
cause fire hazard, damage or malfunction.
Install SG-ONE, so that there is adequate distance from the walls, heat generating bodies, and
peripherals, taking into consideration space requirements for maintenance and ventilation.
Install SG-ONE on 35mm DIN rails with BNL6 mounting clips (sold separately) on both sides of
SG-ONE.
Wire the connectors with conforming cables or ferrules.
Ground FE terminal to assure electromagnetic compatibility.
Use common 0V DC, if different power supplies are used for SG-ONE and other devices (ex.
safety light curtain.
Wire the inputs and outputs so that they are separated from power lines.
When overcurrent flows into output terminals, the protective function turns off the output. However,
when overcurrent status lasts long, internal protective elements will fuse. To protect the internal
elements, insert fuses of double the rated value to each terminal.
Use IEC60127 approved fuses on the power line of SG-ONE. (This is required for equipment
incorporating SG-ONE that is destined for Europe.)
When disposing of SG-ONE, handle it under the laws and regulations of the country in which it is
disposed.
Summary of Contents for SG EASY One
Page 1: ...Safety Control Unit INSTRUCTION MANUAL...
Page 34: ......
Page 70: ...5 28 Using an DATALOGIC AUTOMATION light curtain SE series as S1 S2...
Page 71: ...5 29 Timing chart Logic 3...
Page 74: ...5 32 Logic circuit Logic 4...
Page 80: ...5 38 Timing chart Logic 4...
Page 81: ...5 39...