5-19
Timing chart (Logic 2)
Safety input : X0
Manual start input
: X16
Safety output :
Y0,Y1,Y2,Y3
Monitor output for
X0 and X1 : Y4
Monitor output for
safety output :
Y12,Y13
RUN monitor :
Y16
Solenoid output :
Y17,Y20
Power ON
Safety output ON
Off delay
time
Safety input : X1
(X2, X4 and X6 are OFF and X3, X5, X7 and
X10...X13 are ON in this timing chart.)
Safety input : X0
Control start input
: X17
Safety output :
Y0,Y1,Y2,Y3
Monitor output for
X0 and X1 : Y4
Monitor output for
safety output :
Y12,Y13
RUN monitor :
Y16
Solenoid output :
Y17,Y20
Power ON
Safety output ON
Off delay
time
Safety input : X1
Min. 0.1s
1.Case to use the manual start input (X16)
2.Case to use the control start input (X17)
0.1s...5s
Max. 6s
Max. 6s
(Note
)
Note:
When the input time difference for the dual channel safety inputs is 0.5s or more, an input monitor error is detected.
Refer to the following "Logic functions" for details.
(Note
)
Max. 0.1s
(Note
)
Max. 0.1s
(Note
)
(X2, X4 and X6 are OFF and X3, X5, X7 and
X10...X13 are ON in this timing chart.)
Initialization
Initialization