5-69
Timing chart (Logic 7)
Safety input : X0
Safety output 1 :
Y0,Y1
Monitor output for
X0 and X1 : Y4
Monitor output for
safety output 1 :
Y12
Solenoid output:
Y17
Power ON
(X4, X5, X10, X11 are ON in this chart.)
Safety input : X2
Safety input :
X6,X7
Control start input
: X12
Safety output 2 :
Y2,Y3
Monitor output for
safety output 2 :
Y13
Solenoid output:
Y20
Safety output 2
ON
Off delay
time
Off delay
time
Safety output
all ON
Safety output
all ON
Manual start input
: X13
Monitor output for
X2 and X3 : Y5
Monitor output for
X6 and X7 : Y7
1. Example to use manual start input (X13) which does not
detect adhesion of the start switch on partial stop.
RUN monitor :
Y16
0.1s...5s
Safety output 1
ON
Off delay
time
Min. 0.1s
Max 6s
0.1s...5s
Safety input : X1
(Note 1
)
(Note 1
)
Safety input : X3
Note 1: When the input time difference of the dual channel safety inputs is 0.5s or more, an input monitor error is detected.
Refer to the following "Logic functions" for details.
Note 2: Example to turn on the control start input (X12) before turning on the manual start input (X13).
Max. 0.1s
Max. 0.1s
Max. 0.1s
(Note 1
)
(Note 1
)
Min. 0.1s
Min. 0.1s
Max. 0.1s
(Note 2
)
Initialization
Summary of Contents for SG EASY One
Page 1: ...Safety Control Unit INSTRUCTION MANUAL...
Page 34: ......
Page 70: ...5 28 Using an DATALOGIC AUTOMATION light curtain SE series as S1 S2...
Page 71: ...5 29 Timing chart Logic 3...
Page 74: ...5 32 Logic circuit Logic 4...
Page 80: ...5 38 Timing chart Logic 4...
Page 81: ...5 39...