2-3
General specifications
Operating conditions
Operating temperature
(Surrounding air
temperature)
-10 to +55°C (no freezing)
Relative operating humidity
10 to 95% (non-condensing)
Storage temperature
-40 to +70°C (no freezing)
Relative storage humidity
10 to 95% (non-condensing)
Pollution degree
2
(
IEC/EN 60664-1
Degree of protection
IP20 IEC/EN 60529
Corrosion immunity
Atmosphere be free from corrosive gas
Operation: 0 to 2,000m (0 to 6,565 feet)
Altitude
Transportation: 0 to 3,000m (0 to 9,840 feet)
Vibration resistance
Vibration
(
IEC/EN 61131-2:
5 to 8.4 Hz amplitude 3.5 mm,
8.4 to 150 Hz acceleration 9.8 m/s
2
(1G),
2 hours per each of XYZ axes
Bump (IEC/EN 61496-1):
Acceleration 98 m/s
2
(10G), 16ms duration, 1000 times per
each of XYZ axes
Shock resistance
147 m/s
2
(15G), 11 ms duration, 3 times per each of XYZ axes
(IEC/EN 61131-2)
Connector durability
50 times maximum
Operation strength of
configuration switches
100 operations maximum (per 1 switch)
Operation strength of
enter button
1000 operations maximum
Enclosure material
modified-Poly Phenylene Ether (m-PPE)
Weight Approximately
330g
Electrical conditions
Rated voltage
24V DC
Allowable voltage range
20.4V DC to 28.8V DC
Maximum power
consumption
48W (at 24V DC, all inputs and outputs are ON,
includes output loads)
Allowable momentary
power interruption
10ms minimum (at rated voltage DC)
ON to OFF: 40 ms maximum
Note1
: 100ms maximum
Note2
Reaction time
OFF to ON: 100 ms maximum
Note3
Start-up time
Note4
6s
maximum
Between live part and FE terminal: 500VAC, 1 minute
Dielectric strength
Between enclosure and FE terminal: 500VAC, 1 minute
Between live part and FE terminal: 10M
Ω
minimum
(at 500V DC megger)
Insulation resistance
Between enclosure and FE terminal: 10M
Ω
minimum
(at 500V DC megger)
DC power terminals: 1.0 kV, 50 ns to 1 µs
Noise immunity
(Noise simulator)
I/O terminals: 2.0 kV, 50 ns to 1 µs (with coupling adapter)
Inrush current
25A maximum
Grounding
Type D grounding (Type 3 grounding)
Reverse polarity: No operation, no damage
Affect of improper power
supply connection
Improper voltage: Permanent damage may occur
Summary of Contents for SG EASY One
Page 1: ...Safety Control Unit INSTRUCTION MANUAL...
Page 34: ......
Page 70: ...5 28 Using an DATALOGIC AUTOMATION light curtain SE series as S1 S2...
Page 71: ...5 29 Timing chart Logic 3...
Page 74: ...5 32 Logic circuit Logic 4...
Page 80: ...5 38 Timing chart Logic 4...
Page 81: ...5 39...