MATRIX 120™ REFERENCE MANUAL
124
A
OUTPUTS
Two general purpose
non opto-isolated
but short circuit protected outputs are available on
the M12 17-pin connector of the reader.
The electrical features of the two outputs are the following:
Reverse-Polarity and Short-Circuit Protected
V
OUT
(I
LOAD
= -100 mA) max = 28.3 Vdc (when using 30 Vdc power supply)
V
OUT
(I
LOAD
= 100 mA) max = 1.7 Vdc
I
LOAD
max = 145 mA
The pinout is the following:
Pin
Name
Function
9
O1
Configurable digital output 1
8
O2
Configurable digital output 2
2
GND
Ouptut reference signal
NOTE:
These outputs become
opto-isolated
when connected to the CAB-
1011 accessory cable and acquire the electrical features described in par.
4.5.
The output signals are fully programmable being determined by the configured
Activation/Deactivation events, Deactivation Timeout or a combination of the two. For further
details refer to the Help On Line page for the Output Setup step in DL.CODE.
PNP
Matrix 120
™
USER INTERFACE
9/8
2
Vdc
Figure 72 - PNP Output Connection