ENC58 PROG
27
For any information on the electrical connection of the Counting
direction input refer to the sections “4- Electrical connection“ on page
7 and “4.9 Counting direction input“ on page 10.
WARNING
After having set the new counting direction it is necessary to set also
the Index pulse.
5.4.1 Loading the encoder configuration from a file
Load config
The
Load config
button allows to load an encoder configuration you
have previously saved to a file having .cfg or .hex extension. For
example, it can be useful to restore the encoder default parameters
by uploading the ENC58_default.cfg configuration file that can be
found inside the ENC58_Programming interface.zip compressed
folder.
To load an encoder configuration that you have previously saved
press the
Load config
button (or otherwise as an alternative you can
press the
Load config
command in the File menu). As soon as you
press the button, the Open dialogue box appears on the screen. You
have to select the folder and then the file where the configuration has
been saved. When you press the OPEN button to confirm, the
dialogue box closes and the
Would you like to update also encoder
parameters?
message appears after a few seconds. If you choose
YES, the configuration parameters are updated in both the
programming interface and the encoder; otherwise, if you press NO,
the configuration parameters are updated only in the programming
interface, they are not downloaded to the encoder. In the Messages
section below in the page the
Beware!!! Displayed parameters could
differ from encoder parameters!!
message warns of occurrence and
the Load config button starts blinking red.
5.4.2 Saving the encoder configuration to a file
Save config
The
Save config
button allows to save the current encoder
configuration -i.e. the values currently set in the programming
interface- to a file having . cfg or
.hex extension. As soon as you press the
Save config
button (or
otherwise as an alternative you press the
Save config
command in
the File menu) the
Save as
dialogue box appears on the screen: you
have to enter the file name (you can also specify the file extension
choosing between .cfg and .hex) and choose the path where the file
has to be located. When you press the
SAVE
button to confirm, the
dialogue box closes.