DS8110 REFERENCE MANUAL
62
4
Field Name
Action/Definition
Active Level
Select
Active Open
or
Active Closed
from the
drop-down list to choose the active state of the
input.
Active Open
: The input is active when
there is no current flowing through IN
pins. The input from the verify mode
source is normally closed. The scanner
goes into trigger mode when the input
source is opened.
Active Closed
: The input is active when
current flows through IN pins. The input
from the verify mode source is normally
opened. The scanner goes into trigger
mode when the input source is closed.
Wrong Code
Tx
Select the check box to enable the transmission
of the Wrong Code (Non-Valid Code).
Wrong String
Tx
Select the check box to enable the transmission
of the Wrong String (Non-Valid String) message.
Wrong String
(max. 128
chars)
Enter a text string to be sent in case of a
mismatch (wrong code read/non-valid code).
Beam Shutter Settings
Beam Shutter
Select
Disabled
,
Triggered
, or
Enabled
from the
drop-down list. The Beam Shutter turns the laser
off. The Beam Shutter option can be used to
increase the overall laser diode life when used in
high ambient temperature applications (over 35°
C); reduce power consumption; and to turn off the
laser for safety purposes.
Disabled
: The laser is always on.
Triggered
: The laser is turned off as soon
as the code(s) are read or when the
reading phase ends. The laser is turned
on again when the next reading phase
starts.
Enabled
: The laser is always off and all
operations are suspended.
2 Inputs
Used
The reading phase is defined by 2 inputs. It starts when the
Start
Input
is activated and stops when the
Stop Input
is deactivated
(unless the
Extended Phase
is enabled).
Trigger Source
Extended
Phase
Available only for the
On Line/2 Inputs
option. If
checked, it allows the
Stop Input
to end the
reading phase only if the
Start Input
is also
deactivated.
Summary of Contents for DS8110
Page 1: ...REFERENCE MANUAL DS8110 Barcode Scanner ...
Page 40: ...DS8110 REFERENCE MANUAL 28 3 Figure 25 DS8110 Array Tunnel to SC5000 alternate with CBX ...
Page 52: ...DS8110 REFERENCE MANUAL 40 3 Figure 35 OEK 4 95B082050 Encoder Tachometer Wiring NPN Output ...
Page 54: ...DS8110 REFERENCE MANUAL 42 3 Figure 37 OEK 4 95B082050 Encoder Tachometer Wiring PNP Output ...
Page 56: ...DS8110 REFERENCE MANUAL 44 3 3 13 2 Powered Outputs Figure 40 Powered Outputs NPN PNP ...
Page 249: ...BARCODE SCANNING FEATURES 237 5 Figure 69 Reading Diagram DS8110 2100 0 33mm 13mil ...
Page 250: ...DS8110 REFERENCE MANUAL 238 5 Figure 70 Read Chart DS8110 2100 0 38mm 15mil ...
Page 251: ...BARCODE SCANNING FEATURES 239 5 Figure 71 Read Chart DS8110 2100 0 50mm 20mil ...
Page 253: ...BARCODE SCANNING FEATURES 241 5 Figure 73 Reading Diagram DS8110 2200 0 25mm 10mil ...
Page 254: ...DS8110 REFERENCE MANUAL 242 5 Figure 74 Reading Diagram DS8110 2200 0 30mm 12mil ...
Page 255: ...BARCODE SCANNING FEATURES 243 5 Figure 75 Reading Diagram DS8110 2200 0 33mm 13mil ...
Page 256: ...DS8110 REFERENCE MANUAL 244 5 Figure 76 Reading Diagram DS8110 2200 0 38mm 15mil ...
Page 281: ......