Field Name
Action/Definition
NORMAL
When the Priority Filter Type is set to Normal, the operators
used in the Logical Combination Rule string have the
following meaning:
& = AND operator which separates a group from
the previous/following one;
^ = The priority is given to the code label indicated
to the left of the operator. If this code is read, the
group is in Good Read independent from any other
code in the same group.
Example:
Logical Combination Rule = 1^2&5^3^4&6^7 (3 groups)
Results Without Priority Filter:
Group 1 - read either code 1 or 2 = Good Read;
read both code 1 and 2 = Multiple Read
Group 2 - read either code 5 or 3 or 4 = Good
Read; read any combination = Multiple Read
Group 3 - read either code 6 or 7 = Good Read;
read both code 6 and 7 = Multiple Read
Results With Priority Filter:
Filter Enabled on Groups = 1,2
Group 1 - read code 1 = Good Read independent
from reading code 2
Group 2 - read code 5 = Good Read independent
from reading code 3 or 4; read code 3 = Good
Read independent from reading code 4
Group 3 - read either code 6 or 7 = Good Read;
read both code 6 and 7 = Multiple Read
ADVANCED
When the Priority Filter Type is set to Advanced, the
Priority Filter Advanced String applies to the Logical
Combination Groups. This string must correspond to the
order of the groups defined in the Logical Combination
Rule string.
The following operators can be used:
& = Code group separator. This operator separates
a group from the previous/following one;
^ = The priority is given to the code label indicated
to the left of this operator. If this code is read, the
group is in Good Read independent from any other
Summary of Contents for DS8110
Page 1: ...REFERENCE MANUAL DS8110 Barcode Scanner ...
Page 40: ...DS8110 REFERENCE MANUAL 28 3 Figure 25 DS8110 Array Tunnel to SC5000 alternate with CBX ...
Page 52: ...DS8110 REFERENCE MANUAL 40 3 Figure 35 OEK 4 95B082050 Encoder Tachometer Wiring NPN Output ...
Page 54: ...DS8110 REFERENCE MANUAL 42 3 Figure 37 OEK 4 95B082050 Encoder Tachometer Wiring PNP Output ...
Page 56: ...DS8110 REFERENCE MANUAL 44 3 3 13 2 Powered Outputs Figure 40 Powered Outputs NPN PNP ...
Page 249: ...BARCODE SCANNING FEATURES 237 5 Figure 69 Reading Diagram DS8110 2100 0 33mm 13mil ...
Page 250: ...DS8110 REFERENCE MANUAL 238 5 Figure 70 Read Chart DS8110 2100 0 38mm 15mil ...
Page 251: ...BARCODE SCANNING FEATURES 239 5 Figure 71 Read Chart DS8110 2100 0 50mm 20mil ...
Page 253: ...BARCODE SCANNING FEATURES 241 5 Figure 73 Reading Diagram DS8110 2200 0 25mm 10mil ...
Page 254: ...DS8110 REFERENCE MANUAL 242 5 Figure 74 Reading Diagram DS8110 2200 0 30mm 12mil ...
Page 255: ...BARCODE SCANNING FEATURES 243 5 Figure 75 Reading Diagram DS8110 2200 0 33mm 13mil ...
Page 256: ...DS8110 REFERENCE MANUAL 244 5 Figure 76 Reading Diagram DS8110 2200 0 38mm 15mil ...
Page 281: ......
Page 282: ......