DS8100A REFERENCE MANUAL
28
3
The driving logic of the input signals may be powered, for convenience, with the voltage
supply at the CBX terminal block spring clamps (V+) and (V-). In this case, however, the
device is no longer electrically isolated. The voltage available on pins V+ and V-, is physically
the same as the input power for the scanner (Vdc and GND).
INPUT 1 (EXTERNAL TRIGGER/PS) CONNECTIONS USING DS8100A POWER
(brown)
(black)
(blue)
MEP-593 PH-1 Photocell (PNP)
Figure 24
– MEP-593 PH-1 (PNP) External Trigger/PS Using DS8100A Power
Power to
Input
Photocell
Signal
Photocell
Reference
NPN Photocell
Figure 25 - NPN External Trigger/PS Using DS8100A Power
INPUT 1 (EXTERNAL TRIGGER/PS) CONNECTIONS USING EXTERNAL POWER
External Device
Ground Reference
Input
Signal
Figure 26 - PNP External Trigger/PS Using External Power (i.e. PLC signal)
External Device
Power Reference
Input
Signal
Figure 27 - NPN External Trigger/PS Using External Power (i.e. PLC signal)