DS8100A REFERENCE MANUAL
20
3
The table below gives the pinout of the CBX100/500 terminal block connectors. Use this
pinout when the DS8100A reader is connected by means of the CBX100/500:
CBX100/500 Terminal Block Connectors
Group
Name
Function
Input Power
Vdc
Power Supply Input V
GND
Power Supply Input Voltage -
Earth
Protection Earth Ground
External Trigger
(PS) Input
+V
Power Source
– External Trigger
I1A
External Trigger A (polarity insensitive) for PS
I1B
External Trigger B (polarity insensitive) for PS
-V
Power Reference
– External Trigger
Encoder or
Generic Input
+V
Power Source
– Inputs
I2A
Input 2A (polarity insensitive) for Encoder
I2B
Input 2B (polarity insensitive) for Encoder
-V
Power Reference
– Inputs
Outputs
+V
Power Source
– Outputs
-V
Power Reference
– Outputs
O1+
Output 1+
O1-
Output 1-
O2+
Output 2+
O2-
Output 2-
Other I/O
(CBX500 only)
O3A
Output 3A (polarity insensitive)
O3B
Output 3B (polarity insensitive)
+V
Power Source
– Other I/O
I3A
Input 3A (polarity insensitive)
I4A
Input 4A (polarity insensitive)
-V
Power Reference
– Other I/O
I34B
Input 3B and 4B (common) (polarity insensitive)
I34B
Input 3B and 4B (common) (polarity insensitive)
Auxiliary Interface
TX
Auxiliary Interface TX
RX
Auxiliary Interface RX
SGND
Auxiliary Interface Reference
ID-
NET™
REF
Reserved
ID+
Reserved
ID-
Reserved
Network
Shield
Network Cable Shield
RS232
RS485FD
RS485HD
Main Interface
TX
TX+
RTX+
RTS
TX-
RTX-
RX
*RX+
CTS
*RX-
SGND
SGND
SGND
*
Do not leave floating, see par. 3.2.2 for connection details.
CAUTION
Do not connect GND and SGND to different (external) ground references.
GND and SGND are internally connected through filtering circuitry which
can be permanently damaged if subjected to voltage drops over 0.8 Vdc.
CAUTION
DS8100A scanners do not support Host Interface Modules with the
CBX500. Use the CBX800 Gateway for Host Interface Applications,
(Fieldbus and non Fieldbus).