READING FEATURES
87
9
Auto PackTrack Setup
1. Click on the Start button and follow the instructions given in the Auto PackTrack
procedure window.
The first message is sent to the slaves and their status is shown in the synoptic buttons
at the top of the window.
The scanner status indicated by each synoptic button has the following convention:
Color
Symbol Meaning
Grey
xx-U
slave xx cannot be calibrated - calibration is not supported by scanner
software version
Red
xx-U
slave xx can be calibrated but the calibration procedure fails either barcode
reading or verification
Red
xx-L
slave xx can be calibrated - is Lost stops responding during the procedure
Aqua
xx-I
slave xx can be calibrated - is in the Initial state ready to be calibrated
Yellow
xx-N
slave xx can be calibrated - is calibrated but Not verified
Green
xx-C
slave xx calibrated - is calibrated and verified
The symbol
xx
is the number of the slave scanner
01, 02, 03
etc.
2. Follow each step given in the Auto PackTrack procedure window. The instructions and
summary of each step are written in the terminal area of the window. The Synoptic
buttons report the slave scanner status throughout the procedure.
Basically, place the PCT-8000 onto the moving conveyor, before the PS Line (reference
point) and parallel to a conveyor edge (i.e. right-hand edge) with its arrow in the same
direction as the conveyor movement. Let it pass through the reading station.
NOTE
If there are any nodes that show as
U
or
L
, then you should Stop the
procedure and correct the problem. If the nodes respond with
I
,
N
, or
C
then
you can Continue with the procedure.