Instruction
Manual
DataVS1
Series
35
Selection of the inspection number 8
Protocol selection
To enable the standard protocol on the sensor select Basic Inspection Selection protocol radio button
from Input config menu.
Adjust minimum Pulse duration slider according to the width of pulses received by the sensor;
minimum pulse duration set on the sensor must be lower than pulse width used for changing current
inspection.
Inspection switch timing
Because of Inspection loading can take some processing time (basically the sensor needs to perform
an Inspection teaching phase on the reference image before going in run mode), a unique and
definitive timing of the inspection change process is not available because it will depend on the
inspection time itself.
If the inspection use very fast tools, for example Position or Width, it will be quite fast (hundred of
milliseconds), if the inspection is quite slow, for example a difficult pattern match, the delay will be
greater maybe in the 1-2 seconds range.
During the inspection switch process, the sensor stops acquiring new images and enter an idle status.
When the switch is complete, the sensor blinks once and then starts the new inspection activity.
Anyway it is possible to check the current running inspection using the Graphic User Interface.