Protocol Selection
To enable expert protocol select Advanced Inspection Switching Protocol. Adjust Minimum Pulse
Duration value according to pulses duration your SVS will receive.
Press TEACH button to save your configuration.
6.6.3.
Digital Teach In
Digital Teach In function consists in sending to the sensor a digital pulse on PIN 1. The digital pulse
must have a minimum duration specified through the Minimum Pulse Duration slider available inside
Input pin setup menu: all pulses having a duration higher than the minimum expected are accepted by
the sensor.
After receiving the Teach In request on PIN 1 the sensor will grab a new Reference Image and perform
a new Teach phase on the current running Inspection.
Note: the sensor will not send any acknowledge to the digital Teach In request.
To enable digital Teach In function through just select one of the following options from Input Pin setup
menu:
Tach: only digital teach in will be enabled.
Advanced Inspection Selection Pt Teach: both digital teach In and Advanced
Inspection Switching Protocol will be enabled. In this way the digital Teach In request
corresponds to an Inspection Selection request where the slot number of the selected
Inspection is the current running one.
6.7.
Password
In the password menu the user can set a password to protect the system. This protects the sensor
against accidental or unauthorised modifications. The password is disabled by default. To set a new
password, use the
ARROW
buttons to select
Enable
and then press
SET
to confirm.