14
NOTE:
if no inspection is saved on the DataVS1 sensor the system will display the "Vision Tool"
menu from where the user can select the control to be used. For further details, please refer to the
paragraph marked with the
symbol on Page 14. The camera settings explained in this section can
be performed at any moment in time.
To configure the inspection option it is necessary to start from Setup Mode. Press the
STATUS
button
twice to enter Start-up Mode. The green Set/Net LED will light up and the monitor will display the
following image.
As you can see in the image, the VSC screen is split into two main areas: the field range of the
camera and the settings and options available.
The image acquired by the sensor is displayed in the first area. If the field is out of focus, it is possible
to adjust the focus ring on the sensor (see par.4.1). The configuration options are indicated on the
right hand side of the screen. The user can use the two arrow buttons to scroll the options.
The first step when creating a new inspection rule is to enter the sensor mode settings. To modify
these settings, use the arrows to reach the
CAMERA
icon and then press
SET
.
2 x