D-100 MK2 User Manual Firmware V-6.3
K96D01-EN - 16 -
Supply voltage:
8 to 36VDC
Cranking dropouts:
Survives 0VDC during 100ms. The voltage before surge should be
8VDC minimum
Overvoltage protection:
Withstands 150VDC continuously.
Reverse voltage:
-33VDC continuous
Maximum operating
current:
500mA @ 12VDC. (All options included, digital outputs open.)
250mA @ 24VDC. (All options included, digital outputs open.)
Typical operating current:
250mA @ 12VDC. (all options passive, digital outputs open)
125mA @ 24VDC. (all options passive, digital outputs open)
Measurement range:
0 to 36VDC
Display resolution:
0.1VDC
Accuracy:
0.5% + 1 digit @ 24VDC
3.1. BATTERY VOLTAGE INPUT
3. TERMINAL DESCRIPTIONS