To configure an SLC Series 5 device:
1.
Highlight Find.
2.
Press Enter.
3.
In the Bay field, type the number of the bay you wish to configure.
Acceptable values are 1-16.
4.
The following question appears at the bottom left corner of the
screen:
Bay not there. Wish to add?
Type Y to add the bay. If you type N, the screen prompts you for
another bay.
5.
In the MAP Dsp field, type the location in the MAP’s memory
where the SLC Series 5 bay resides. Acceptable memory locations
are 1-64 or 1-128, depending on how many alarm displays the MAP
reports.
6.
Press Enter.
If the message Memory Conflict - Any key to cont: appears, it
means the display is full. You must type a different display location
in the MAP Dsp field. If you are having difficulty locating unused
memory, see the Reports section of this chapter for viewing a
Memory Available report.
Bay Alarms Input/Control
1.
In the Port field, type the SmartMAC port number MATs and
CPMs connect to. Acceptable values are 1-64.
2.
Press Enter.
3.
In the MAT field, type the SLC Series 5 bay MAT address. Accept-
able values are 1-128. Press Enter.
4.
In the Dsp field, type the MAP memory display number the MAT
resides in. Acceptable values are 1-128. Press Enter.
5.
In the CPM field, type the SLC Series 5 bay CPM address. Accept-
able values are 1-128. Press Enter.
6.
In the Dsp field, type the MAP memory display number the CPM
resides in. Acceptable values are 1-128. Press Enter.
7.
In the ACO Control Point field, type the ACO control point for ac-
knowledged alarms. Acceptable values are odd numbers between
1-15.
MAP SYSTEM DEFINITION
CONTINUED
. . .