VLT 5000 525-690 VAC
VLT 8000 525-690 VAC
VLT 4000 and VLT 6000 525-600 VAC
NOTE
Frame size is used throughout this manual
where ever procedures or components differ
between drives based upon the unit's physical
size. Refer to these tables to determine D1, D2,
and E1 frame size definitions.
VLT 5000 380-500 VAC
VLT 8000 380-480 VAC
VLT 4000 and VLT 6000 380-460 VAC
380-460 VAC
Frame
Model
VLT 4000
VLT 6000 HVAC
HP @460 VAC kW @400 VAC
4152, 6152
150
110
D1
4202, 6172
200
132
D1
4252, 6222
250
160
D2
4302, 6272
300
200
D2
4352, 6352
350
250
D2
4452, 6402
450
315
E1
4502, 6502
500
355
E1
4602, 6552
550 (600)*
400
E1
4652, 6602
600
450
E1
Power
*unit can attain 600 hp
380-480 VAC
Frame
Model
VLT 8000 AQUA
HP @460 VAC kW @400 VAC
8152
150
110
D1
8202
200
132
D1
8252
250
160
D2
8302
300
200
D2
8352
350
250
D2
8452
450
315
E1
8502
500
355
E1
8602
550 (600)*
400
E1
8652
600
450
E1
Power
*unit can attain 600 hp
380-500 VAC
Frame
Model
VLT 5000-P
VLT 5000 FLUX
HP @460 VAC kW @400 VAC
kW @500 VAC
5122
125 / 150
90 / 110
110 / 132
D1
5152
150 / 200
110 / 132
132 / 160
D1
5202
200 / 250
132 / 160
160 / 200
D2
5252
250 / 300
160 / 200
200 / 250
D2
5302
300 / 350
200 / 250
250 / 315
D2
5352
350 / 450
250 / 315
315 / 355
E1
5452
450 / 500
315 / 355
355 / 400
E1
5502
500 / 600
355 / 400
400 / 500
E1
5552
550 / 600
400 / 450
500 / 530
E1
Power
High Overload / Normal
525-690 VAC
Frame
Model
VLT 8000 AQUA
HP @575 VAC kW @690 VAC
8052
50
45
D1
8062
60
55
D1
8072
75
75
D1
8102
100
90
D1
8122
125
110
D1
8152
150
132
D1
8202
200
160
D1
8252
250
200
D2
8302
300
250
D2
8352
350
315
D2
8402
400
400
D2
8502
500
500
E1
8602
600
560
E1
8652
650
630
E1
Power
525-690 VAC
Frame
Model
VLT 5000-P
HP @575 VAC kW @690 VAC
5042
40 / 50
37 / 45
D1
5052
50 / 60
45 / 55
D1
5062
60 / 75
55 / 75
D1
5072
75 / 100
75 / 90
D1
5102
100 / 125
90 / 110
D1
5122
125 / 150
110 / 132
D1
5152
150 / 200
132 / 160
D1
5202
200 / 250
160 / 200
D2
5252
250 / 300
200 / 250
D2
5302
300 / 350
250 / 315
D2
5352
350 / 400
315 / 400
D2
5402
400 / 500
400 / 500
E1
5502
500 / 600
500 / 560
E1
5602
600 / 650
560 / 630
E1
High overload / Normal
Power
525-600 VAC
Frame
Model
VLT 4000
VLT 6000 HVAC
HP @575 VAC kW @550 VAC
4102, 6102
100
75
D1
4122, 6122
125
90
D1
4152, 6152
150
110
D1
4202, 6172
200
132
D1
4252, 6222
250
160
D2
4302, 6272
300
200
D2
4352, 6352
350
250
D2
4402, 6402
400
315
D2
4502, 6502
500
400
E1
4602, 6602
600
450
E1
4652, 6652
650
500
E1
Power